Product Detail :
|
Replacement of existing 66 kV SC line with Rabbit conductor on fabricated lattice towers by 66 kV SC line on DC towers with Coyote conductor from lapping Point of 66/11W Venkatapura substation MN.. Point of proposed 220 kV Mitternari substation in existing corridor fora distance of 49.555 Km. Establishing 1*10 MVA 110/11 substation AT J.C PURA IN C.N HALLI AND CONSTRUCTION OF 110KV LILO LINE FROM EXISTING 110KV K.B CROSS-THIMMANHALLI LINE FOR A A DISTANCE OF ABOUT 3.151KM WITH LYNX CONDOCTOR. Construction of 110KV SC line on DC towers with Lynx conductor from existing 110/11kV MaMadapura sub station to existing 110/ 11kV YARAGATTI sub station for a distance of 20.737 Kms along with construction of 110kV terminal bay at existing 110/11 kV marnadapura substation GOKAK TALUK, BELAGAVI DISTRICT AND 110 /11KV YARAGATTI SUBSTATION. Laying of 66KV, 630sQmm single circuit UG CABLE for arranging power supply to M/s South Western Railways, Traction substation at Doddabele Railway Station from existing 66/11kV THyamagundalu substation for a route length of 7.1 Km and construction of 66/11kV terminal bay at existing 66/11kV Thyamagundalu sub station fOr terminating Proposed 66KV 630SQmm UG cable UP to PROPOSSED traction substation Doddabele Railway Station. Construction of following lines and terminal bays in MolakalML TALUK, Chiradurga District(a) Construction additional 66KV SC LINE WITH Coyote conductor from 66/11 kV Hangal Substation to 66/11 kV Rampura substation LILOing at 66/11 kV Nagasamudra Substation for a distance of 26.994 Kms. (b) Construction of 1 no of .kV Terminal Bay at 66/11 kV Rampura substation. (c) Construction of 1 o. of 66/11kV Terminal Bay at 66/11 kV HANGAL Substation. (d) Construction of 2 nos. of . kV Terminal Bays at 66/11 kV Nagasamudra substation. Construction of following lines and terminal bays in KANAKAPURA TALUK, RAMANAGARA District(a) LAYING 66KV 1000SQMM UG CABLE DROM 220/66KV KANAKAPURA SUB STATION TO CTT POINT FOR A DISTANCE OF 4.91KM. (b) Construction of 66KV SC OVER HEAD LINE WITH DRAKE CONDUCTOR ON 110DC TOWERS FROM CTT POINT TO 66/11KV KUNUR SUB STATION FOR A DISTANCE 2.438KM. (C) Construction of ONE NO. OF 66KV TERMINAL BAY EACH AT EXISTING 220/66V KANAKAPURA SUBSTATION AND 66/11KV KUNUR SUBSTATION. Stringing 2nd circuit on existing 66kv davanagere –chitradurga line- 2 from 220kv davanagere sub station to lilo point of 66/11kv anagodu sub station in the existing corridor on dc towers for a distance of 16.105 km with coyote conductor and construction of 1 no of 66kv terminal bay at 220/66/11kv davanagere sub station for terminating 66kv 2nd circuit on existing 66kv davanagere chitradurga line 2 from 66/11kv. Establishing 1x10 WA, 110/11 kV Substation at haridasanahalli in turuvekere Taluk, tumkuru District and construction of 110 kV lilo line from existing 110kV k.b cross- turuvekere line to the proposed 110/11kv haridasanahlli sub station for a distance of 0.22km with lynx conductor in turuvekere tuluk. Establishing 2x10MVA 110/11KV SUB-StatioN AT Bellada Bagewadi and Construction of 110kV LILO line from 110kV HUKKERI-VISHWANATH Sugars line to PROPOSED 110/11kV BelAda BAGEWADI Substation for distance of 2.401 Kms in Hukkeri Taluk. Establishing 2x10MVA 110/11KV SUB-StatioN AT YADGIR NORTH and Construction of 110kV SC LINE ON DC TOWERS FOR A DISTANCE OF 21.519KM FROM EXISTING 110/33/11KV SUBSTATION AT NALWAR TO PROPOSED 110/11KV YADGIR NORTH SUBSTATION ALONG WITH CONSTRUCTION OF 1 NO. OF TERMINAL BAY AT 110/33/11 KV NALWAR SUBSTATION. Establishing 2x10MVA 110/11KV SUB-StatioN AT NANDIYAL (AT 220KV NANDIYAL SWITCHING STATION) AND CONSTRUCTION OF 110KV LILO LNE FROM EXISTING 110KV BASAVANA BAGEWADI- VIJAYAPURA SC LINE TO THE PROPOSED 110/11NANDIYAL SUBSTATION FOR A DISTANCE OF 0.929 KMIN BASAVANA BAGEWADI TALUK. Replacement of rusted 110 kV GI lattice SC Towers along with conductor & ground wire by new 110 kV DC GI T I g 'th Lynx conductor 8 ground wire from Loc. No. 90 to 138 of 110 kV Nare.ra-Kittur SC line for a distance of 15.178 km in Dhanvad/ Belagavi District. Construction of following lines and terminal bays in Chikkaballapur District (a) Stringing of 2ND circuit wig Coyote ACSR conductor on existing DC towers horn 220 kV Miltemari substation to kV Somenehalli substation in existing 66 kVMeternai-Somenahalli line cork. for line length of about 7.108 KM (b) Stringing 2ND circuit line on existing DC Towers by using Coyote ACSR conductor from tapping point of mdsting Gowribidanur-Reresandra SC Line to the existing 66/11 kV Somenahalli Subst.on fora distance of 7.87 Km, (c) Construction of 66 kV DC line with Coyote ACSR conductor from existing 66 kV Peresandra-Magampalli SC Line near Somenahalli tap point to the existing 66/11 kV Nallimaradahalli substation in new corrifor fora distance at 11.847 Km. (d) Stringing 2ND circuit WITH Coyote ACSR conductor on existing DC towers from 66/11 kV Nal
|